39 research outputs found

    Acute modulation of brain connectivity in Parkinson disease after automatic mechanical peripheral stimulation: A pilot study

    Get PDF
    The present study shows the results of a double-blind sham-controlled pilot trial to test whether measurable stimulus-specific functional connectivity changes exist after Automatic Mechanical Peripheral Stimulation (AMPS) in patients with idiopathic Parkinson Disease.Eleven patients (6 women and 5 men) with idiopathic Parkinson Disease underwent brain fMRI immediately before and after sham or effective AMPS. Resting state Functional Connectivity (RSFC) was assessed using the seed-ROI based analysis. Seed ROIs were positioned on basal ganglia, on primary sensory-motor cortices, on the supplementary motor areas and on the cerebellum. Individual differences for pre- and post-effective AMPS and pre- and post-sham condition were obtained and first entered in respective one-sample t-test analyses, to evaluate the mean effect of condition.Effective AMPS, but not sham stimulation, induced increase of RSFC of the sensory motor cortex, nucleus striatum and cerebellum. Secondly, individual differences for both conditions were entered into paired group t-test analysis to rule out sub-threshold effects of sham stimulation, which showed stronger connectivity of the striatum nucleus with the right lateral occipital cortex and the cuneal cortex (max Z score 3.12) and with the right anterior temporal lobe (max Z score 3.42) and of the cerebellum with the right lateral occipital cortex and the right cerebellar cortex (max Z score 3.79).Our results suggest that effective AMPS acutely increases RSFC of brain regions involved in visuo-spatial and sensory-motor integration.This study provides Class II evidence that automatic mechanical peripheral stimulation is effective in modulating brain functional connectivity of patients with Parkinson Disease at rest.Clinical Trials.gov NCT01815281

    Functional cortical source connectivity of resting state electroencephalographic alpha rhythms shows similar abnormalities in patients with mild cognitive impairment due to Alzheimer's and Parkinson's diseases

    Get PDF
    Objective: This study tested the hypothesis that markers of functional cortical source connectivity of resting state eyes-closed electroencephalographic (rsEEG) rhythms may be abnormal in subjects with mild cognitive impairment due to Alzheimer's (ADMCI) and Parkinson's (PDMCI) diseases compared to healthy elderly subjects (Nold). Methods: rsEEG data had been collected in ADMCI, PDMCI, and Nold subjects (N = 75 for any group). eLORETA freeware estimated functional lagged linear connectivity (LLC) from rsEEG cortical sources. Area under receiver operating characteristic (AUROC) curve indexed the accuracy in the classification of Nold and MCI individuals. Results: Posterior interhemispheric and widespread intrahemispheric alpha LLC solutions were abnormally lower in both MCI groups compared to the Nold group. At the individual level, AUROC curves of LLC solutions in posterior alpha sources exhibited moderate accuracies (0.70-0.72) in the discrimination of Nold vs. ADMCI-PDMCI individuals. No differences in the LLC solutions were found between the two MCI groups. Conclusions: These findings unveil similar abnormalities in functional cortical connectivity estimated in widespread alpha sources in ADMCI and PDMCI. This was true at both group and individual levels. Significance: The similar abnormality of alpha source connectivity in ADMCI and PDMCI subjects might reflect common cholinergic impairment. (C) 2018 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved

    Effetto della stimolazione dopaminergica continua sull'assetto recettoriale dopaminergico dei gangli della base: studio di farmacodinamica clinica con infusione continua di farmaci dopaminergici in pazienti affetti da morbo di Parkinson complicato

    No full text
    Dottorato di ricerca in neurobiologia. 11. ciclo. Tutore e coordinatore Anna Maria Giuffrida StellaConsiglio Nazionale delle Ricerche - Biblioteca Centrale - P.le Aldo Moro, 7, Rome; Biblioteca Nazionale Centrale - P.za Cavalleggeri, 1, Florence / CNR - Consiglio Nazionale delle RichercheSIGLEITItal

    The Parkinsonian gait spatiotemporal parameters quantified by a single inertial sensor before and after automated mechanical peripheral stimulation treatment

    Get PDF
    This study aims to evaluate the change in gait spatiotemporal parameters in subjects with Parkinson’s disease (PD) before and after Automated Mechanical Peripheral Stimulation (AMPS) treatment. Thirty-five subjects with PD and 35 healthy age-matched subjects took part in this study. A dedicated medical device (Gondola) was used to administer the AMPS. All patients with PD were treated in off levodopa phase and their gait performances were evaluated by an inertial measurement system before and after the intervention. The one-way ANOVA for repeated measures was performed to assess the differences between pre- and post-AMPS and the one-way ANOVA to assess the differences between PD patients and the control group. Spearman’s correlations assessed the associations between patients with PD clinical status (H&Y) and the percentage of improvement of the gait variables after AMPS (α<0.05 for all tests). The PD group had an improvement of 14.85% in the stride length; 14.77% in the gait velocity; and 29.91% in the gait propulsion. The correlation results showed that the higher the H&Y classification, the higher the stride length percentage of improvement. The treatment based on AMPS intervention seems to induce a better performance in the gait pattern of PD patients, mainly in intermediate and advanced stages of the condition

    Timed Up and Go evaluation with wearable devices: Validation in Parkinson's disease

    No full text
    The Timed Up and Go test (TUG) is used to assess individual mobility. It evaluates static and dynamic balance by means of the total time required to complete the test, usually measured by a stopwatch. In recent years tools based on portable inertial measurement units (IMU) for clinical application are increasingly available on the market. More specifically, a tool (hardware and dedicated software) to quantify the TUG test based on IMU is now available. However, it has not yet been validated in subjects with Parkinson's disease (PD). Thus, the aim of this study is to compare measurements from instrumented TUG tests (or iTUG) acquired by an IMU with those obtained using an optoelectronic system (the gold standard) and by a stopwatch, to gain an in-depth understanding of IMU behavior in computing iTUG in subjects with PD. To do this, three TUG test trials were carried out on 30 subjects with PD and measured with all three systems simultaneously. System agreements were evaluated using Intraclass Correlation Coefficient and Bland-Altman plots. The device tested showed excellent reliability, accuracy and precision in quantifying total TUG test duration. Since TUG is a widely used test in rehabilitation settings, its automatic quantification through IMUs could potentially improve the quality of assessments in the quantification of PD gait ability

    Analyzing gait variability and dual-task interference in patients with Parkinson’s disease and freezing by means of the word-color Stroop test

    No full text
    The ability to carry out two tasks at once is critical to effective functioning in the real world and deficits are termed Dual-task interference or effect—DTE. DTE substantially compromised the gait of subjects with Parkinson’s disease and freezing of gait (PD + FOG), leading to exaggerated slowing, increasing gait dysrhythmicity, and inducing FOG episodes. This study aimed to investigate the DTE in gait variability of subjects with PD and freezing of gait (PD + FOG). Thirty-three patients with PD + FOG and 14 healthy individuals (REFERENCE) took part at this study. Two gait conditions were analyzed: usual walking (single task) and walking while taking the word-color Stroop test (dual task). The computed variables were as follows: gait velocity, step length, step timing, gait asymmetry, variability measures and DTE of each variable. The PD + FOG group has presented negative DTE values for all analyzed variables, indicating dual task cost. The REFERENCE group has presented dual-task benefits for step length standard deviation and step time. Differences between both groups and conditions were found for all variables, except for step time. Taking the word-color Stroop test while walking led to a larger dual-task cost in subjects with PD + FOG
    corecore